AIR- JET SOOT BLOWER.
CLEANING
EXHAUST SECTION
1.
ENSURE AIR
RECEVIER PRESSURE IS MAX (28/29BAR). , IF NOT START AIR COMPRESSOR AND PRESS UP
THE AIR RECEIVER
2.
DRAIN AIR RECEIVER TO REMOVE ACCUMULATED
WATER.
3.
OPEN THE ROOT
VALVE OF THE SOOT BLOWER FULLY ON THE AIR RECEIVER.
4.
DRAIN IF
ACCUMULATAED WATER IN THE AIR LINE NEAR SOOT BLOWER.
5.
OPEN THE STOP VALVE
OF THE RESPECTIVE SOOT BLOWER.
6.
OPERATE THE HANDLE
OF THE SOOT BLOWER. AFTER OPERATION SHUT THE STOP VALVE OF RESPECTIVE SOOT
BLOWER.
7.
OPERATE ALL THE
THREE SOOT BLOWERS IN SEQUENCE. DURING OPERATION IF THE AIR PRESSURE HAS
DROPPED, THE EFFECT OF SWEEPING AWAY SOOT REDUCES; HALT THE OPERATION TILL
PROPER PRESSURE HAS BEEN RESTORED.
8.
SHUT THE ROOT
VALVE OF THE SOOT BLOWER ON THE AIR RECEVIER AND DRAIN THE LINE.
9.
OPERATE SOOT
BLOWERS AS PER REQUIREMENT..
CLEANING THE OIL- BURNING SECTION
1. NORMALLY OPERATE THE SOOT BLOWERS WHEN THE
BURNER FIRES, OR WITH THE F.D.FAN RUNNING.
(I.e.
BURNER OPERATION SWITCH IS IN “MANU” MODE).
2.
OPEN THE ROOT VALVE OF THE SOOT BLOWER
3.
REMOVE THE FORWARD STOPPER FROM THE SOOT BLOWER, PUSH THE SOOT BLOWER
INTO BURNING CHAMBER
& PUT THE SAFETY STOPPER ON THE HANDLE
4. OPEN THE STOP VALVE &
TURN THE HANDLE OF THE SOOT BLOWER TO JET THROUGHOUT THE AREA, THAT IS
LIMITED BY THE STOPPER IN
THE INDICATED DIRECTION.
5. OPRATE FOR ONE MINIUTE, SHUT STOP VALVE,
REMOVE SAFETY STOPPER AND PULLTHE HANDLE OUT AND
APPLY FORWARD STOPPER.
6. SHUT THE ROOT VALVE, AND
DRAIN THE LINE.
NOTE:
1. INFORM BRIDGE BEFORE CARRYING
OUT SOOT BLOW
2. DUTY
OFFICER HAS TO CHECK SOOT OR SPARKS
COMING OUT FROM FUNNEL WHILE CARRYING OUT SOOTBLOWING.
3. SOOTBLOW TO BE CARRIED OUT
ONCE A DAY.
2 comments:
Howdy! I just want to give an enormous thumbs up for the great info you’ve here on this post. I can be coming again to your weblog for extra soon.
Root blowers
Industrial blowers
Some boilers have economizers to improve cycle efficiency by preheating inlet feedwater to the boiler. The economizer uses heat from the boiler exhaust gasses to raise the temperature of the inlet feedwater.