DANGER OF BACKFIRE AND FLASH
BACK OF AUX BOILER
UNBURNT HYDROCARBON GASES PRESENT INSIDE THE FURNACE
OF THE BOILER HAS TO BE PURGED OUT BEFORE ATTEMPTING TO IGNITE THE BURNER.
ACCUMULATION OF HYDROCARBON GASES CAN OCCUR DUE TO
FOLLOWING REASONS:
1) FREQUENT
ATTEMPTS TO IGNITE BURNER WITHOUT ASCERTAINING AND RECTIFYING CAUSES OF
MISIGNITION/MISFIRE.
2) LEAKY STOP
SOLENOID V/VS.
3) IMPROPER
FUEL ATOMISATION LEADING TO IMPINGEMENT AND ACCUMULATION OF FUEL.
4) OBSTRUCTIONS
IN THE UPTAKE CAUSING THE PURGING TO BE INEFFECTIVE.
5) MALFUNCTIONING
OF THE AIR DAMPER CAUSING INSUFFICIENT AIR SUPPLY FOR PURGING.
ANY ATTEMPT TO IGNITE THE BURNER WHEN
THE FURNACE HAS HYDROCARBON GAS ACCUMULATION CAN CAUSE VIOLENT EXPLOSION,
BACKFIRE AND FLASH BACK FROM THE FURNACE.
BACK FIRE CAN CAUSE SERIOUS INJURY TO OPERATING PERSONAL AND VESSEL’S
EQUIPMENTS.
STRICTLY FOLLOW THESE INSTRUCTIONS
DURING BOILER OPERATION:
ONLY QUALIFIED ENGINEERS SHOULD OPERATE THE BOILER
IF THE
IGNITION FAILS FOR 5 SECONDS, RELEASE THE MANUAL IGNITION SWITCH IMMEDIATELY,
ALLOW FOR POST PURGE AND INVESTIGATE THE CAUSE OF FAILURE.
DO NOT TRY
FOR ANOTHER ATTEMPT WITHOUT CARRYING OUT POST PURGE/PRE PURGING OPERATION.
ALWAYS STAND
ON THE SIDE OF THE BURNER ASSEMBLY WHILE FIRING THE BOILER MANUALLY.
ANY ABNORMAL
ALARM DURING ‘AUTO’ OPERATION SHOULD BE RESET ONLY AFTER INVESTIGATING AND
RECTIFYING THE DEFECT.
DURING
MAINTENANCE, ALWAYS USE PERSONAL PROTECTIVE AIDS. (COTTON COVERALLS, GOGGLES,
FACE SHIELD, FIRE PROOF HAND GLOVES).