MARINESHELF RECENT

Welcome to Marineshelf — new posts regularly Marine Engineering tips & DIY guides Subscribe for updates Welcome to Marineshelf— new posts regularly Merchant Navy tips & DIY guides Subscribe for updates

Thursday, March 13, 2014

METAL INERT GAS (MIG) OR GAS METAL ARC WELDING (GMAW)

MARINESHELF publishes articles contributed by seafarers and other marine related sites solely for the benefit of seafarers .All copyright materials are owned by its respective authors or publishers.


This process too may be manual or automatic, the difference being that the electrode is consumable, being wound on a reel and fed at a constant rate through powered wire feed rollers, The torch is special, containing the power cable, a contact tube for the wire electrode and a nozzle at the end to direct the gas shield The inert gas is contained in cylinders under pressure and piped to the torch. It may be CO2 (for mild steel), argon for non-ferrous metals, and a C02-02-argon mixture for high strength, corrosion resistant ferrous alloys.


The arc length is controlled by the power source which has variable inductance in the circuit to prevent current surges. The operator has thus to only concentrate on weld deposit. In the automatic process powdered flux may be added to the gas and the electrode wire magnetised, so that the flux clings to it as it enters the weld Pool )


This method is suitable for thin plates in the down hand position with bare wire electrodes upto 1.6 mm diameter. For welding in the ‘overhead and vertical positions a pulsed arc or ‘dip transfer method is used. In this method, as the wire is continuously fed, the arc first is established, the electrode then comes into contact with the plate, the tip melts, gets detached and deposited as a drop on the plate after which the arc re-establishes itself and the process repeats. For thick plates a higher current is used with which a fine spray transfer of the electrode across the arc is achieved with deep penetration.


This method is continuous, gives a good quality weld with no need of finishing and the equipment is portable and suitable for open air work.


TIG WELDING

MARINESHELF publishes articles contributed by seafarers and other marine related sites solely for the benefit of seafarers .All copyright materials are owned by its respective authors or publishers.

A water-cooled non-consumable tungsten electrode shielded by inert gas is used in

a manual or mechanised process. A high frequency discharge or current surge is

used to ignite the arc as striking the arc may contaminate the expensive electrode.

Filler material, which could be waste pieces of the material being welded, may be

added to the weld pool for thicker plates. An AC is preferred over DC as it


(i) Stabilises the arc


(ii) Prevents overheating


Argon is normally used as the shielding gas for aluminium and steel welding while nitrogen or helium is used for copper welding. A ceramic disc directs the gas in a swirling flow, thus forming a shroud around the area. The process is normally used to weld thin sheets less than 6 mm. It is a clean process as the absence of flux results in no formation of slag or contaminating residue. This is beneficial if multi- pass runs have to be made. A skilled welder is required and high quality welds for stainless steels, nickel steels and aluminium alloys can be obtained.

DIFFERENT TYPES OF ELECTRIC WELDING

MARINESHELF publishes articles contributed by seafarers and other marine related sites solely for the benefit of seafarers .All copyright materials are owned by its respective authors or publishers.


DIFFERENT TYPES OF ELECTRIC WELDING


Arc welding    a) Inert Gas Shielded

                        b) Slag Shielded

Inert Gas Shielded                                                         Slag Shielded

 i)  Non-consumable Electrode                                      1) Flux cored process

            1) Plasma arc                                                       2) Shielded Metal Arc 

            2) Carbon arc                                                       3) Submerged arc

            3) Atomic hydrogen                                             4) Stud welding

            4) T.I.G. (argon shielded)


  ii)  Consumable Electrode 

         1) M.I.G. (Argon shielded)


a) Pulse Transfer

                b) Spray Transfer

           2) M.I.G. (CO2 Shielded)

              a) Spray Transfer

                 b) Dip Transfer 

           3)  Flux cored process 


ARC WELDING: -                           Inert Gas      or    Slag
INERT GAS :-           Non consumable Electrodes         Consumable Electrodes
NON CONSUMABLE TYPE :=      Plasma   /    Carbon Di-oxide  /  Argon (T I G)
Consumable Electrodes   :-   MIG(argon) / MIG(CO2) / Flux Coated
SLAG   :--  Flux coated / Shrouded  metal ARC / Submerged arc / stud welding

Faults :-  
Lack of  root penetration 
Undercut
Blow holes
Overlap
Side fusion
Slag inclusion
Minimum penetration